Electronics Options

Each Rheotherm flow meter consists of one of our sensors with one of a number of available electronics configurations. The best choice of electronics depends on the application parameters and other options you may need; Contact Us for help in selecting the most appropriate unit for you. The available electronics choices are:

Flow sensors with integral electronics210 – This is our most frequently recommended unit for common applications. The Model 210 is a linear meter with the electronics and sensor integrated into one unit. Another version (210R) is also available with the electronics separate from the sensor. Click for more information about the Model 210 (product brochure).

213 – For measuring bi-directional flow of liquids or gases. Another version (213R) is also available with the electronics separate from the sensor.

111D – linear electronics; up to 20:1 turndown

112 – linear electronics; up to 100:1 turndown

100 – nonlinear electronics (output approximately a logarithmic function)

400 – Flow indicator – low cost method of determining the existence and magnitude of flow.

100CS – flow switch with single relay output (SPDT), field-adjustable setpoint

100FS – flow switch with electronics separate from sensor to accommodate additional output options

 

 

ModelNEMA.4NEMA.4XNEMA.4X SSNEMA.7
(expl.proof)
NEMA.1
(table.top)
Panel MountMounting Plate
210CheckCheckTiny logo
210RCheck • Check
213CheckCheck Tiny logo
213RCheckTiny logo Check
111DCheck • •
100Check • •
400 CheckCheck Tiny logo
100CS CheckCheck Tiny logo
100FS Check •
 ……………Check = Standard• = OptionalTiny logo = Contact Us

……………………..FLOW OUTPUT

Model4-20.mA
(linear)
4-20.mA
(log)
4-20.mA
w/HART
RS-232
Packet
RS-485
Modbus
0..5V0..10VPulsePulse
Open Collector
210Check*Check* Check*
210RCheck*Check*Check*
213Check* Check*Check*
213RCheck*Check*Check*
111DCheck •
100Check
400
100CS
100FS
Check = StandardCheck* = Designate desired output• = Optional
|

ADDITIONAL OUTPUTS

ModelTemp.
4..20 mA
Temp.
0..5V
Temp.
0..10V
Single
SPDT
Time Delay
(for SPDT)
2nd SPDTDPDT
210
210R • •
213
213R • •
111D • •
100 • •
400 Check• * •
100CS Check
100FSCheck •
 ……………Check = Standard• = Optional•* = One SPDT only
Model24 VDC12 VDC115 VAC230 VAC
210Check
210RCheck
213Check
213RCheck •
111D •Check Check
100Check Check
400 • Check Check
100CS Check* Check* Check
100FS Check •CheckCheck
Check = StandardCheck* = Designate desired power• = Optional
|